The following procedure works with windows xp through windows 10 for 32 bit and 64 bit operating systems whether you are using the white allen bradley 1747uic or the black 1747uic. Allen bradley 1747uic slc 500 usb to dh485 programming. Alternate 32 bit method go back to configure drivers in rslinx, delete our df1 driver, select dh485 uic devices from the drop down, and click the add new. This protocol requires a special usb converter, the 1747uic, which you can. Configuring including installing allen bradley rslinx. We purchased a 1747uic module and did some preliminary testing with an earlier version of rslinx 2. If you have any issues you can call or email us for support, we also offer a full refund if you are not happy. We have also created a procedure that will be mailed on the cd with the drivers to show you the settings that are needed or can be found on our. Then from the available driver types drop down list select rs232 df1 devices. Compatible processors slc 500 1747l20, 1747l30, 1747l40 slc 501 1747l511, 1747l512, 1747l5, 1747l514 slc 502 1747l521, 1747. Rockwell automation 1747uic universal serial bus to dh485. Rok is a worldleading provider of industrial automation power, control and information solutions that help customers meet their manufacturing. Videos you watch may be added to the tvs watch history and influence tv recommendations. Jun 12, 2019 allenbradley 1747uic 1747uic interface module.
Usb 1747uic windows 7 64 and 32 bit allen bradley dh485. Slc 500 rs232 to rs485 interface converter 3 publication 1747in024aenp september 2002 current driver and rslinx release make sure you have the newest 1747pic driver and rslinx release for your operating system, particularly if you are using windows 2000, windows xp, or later operating system. Like ab uses what they call dh485 and sells a 1747uic converter to do the job with one cable. Alternate 32 bit method g o back to configure drivers in rslinx, delete our df1 driver, select dh485 uic devices from the drop down, and click the add new button. Allen bradley 1747 uic usb to dh485 usb to 1747 pic ab plc programmer calbe. Rockwell automation releases usbtodh485 interface converter.
Allen bradley 1747uic usb to dh485 usb version 1747pic. You also have an option to view firmware compatibility for a given product. In the rslinx software form menu, select communications configure drivers. The 1747uic has a universal serial bus usb transfer speed of 12 mbps with rslinx software. Allen bradley 1747uic usb to dh485 usb version 1747pic slc500. Access the rockwell automation download center to keep your products current. This includes the latest addon profiles aops, drivers, macros, electronic data sheets, sample code, and software activations. Usb to serial chipset inside the device is the correct ftdi chipset just like in the 1747uic from ab. See configure the 1747uic interface converter in rslinx on page 11.
Device works exactly the same way the real ab 1747uic works. I have been trying to set up rsview32 to communicate via rslinx with an slc503 ab controller through its dh485 port using a 1747uic adapter. If playback doesnt begin shortly, try restarting your device. Type in the catalog numbers andor descriptions of the products you wish to find. A straight usb to rs232 converter will not work with the pic driver. In the mean time, rockwell has released a firmware utility for its 1747 uic which allows switching between 9,600 and. Make sure you have a recent version of rslinx, download guide. Unplug the 1747uic interface converter from the computers. Manage your ecommunications subscription preferences.
Allen bradley 1747uicusb to dh485 usb to 1747pic ab plc programmer calbe. I managed to stru 1747uic driver installation problem programmable logic controllers plc engtips. Windows 7810 32bit and 64bit with the 64bit you will need a different driver setup. Personalize your experience information, services, support and more. If it isnt showing up, then navigate the the 1747uic directory or the cd when prompted. Create a new df1 driver in rslinx and try connecting without the uic and see what happens. To regain comms youll have to edit your driver in rslinx to match the. Allen bradley 1747uic usb to dh485 usb version 1747 pic slc500. How to connect to an allenbradley slc 500 plc dmc, inc. Rockwell offers a product with a part number of 1747uic. Ask us about allenbradley 1747uic, usb to dh485 interface converter repairs.
Before using the 1747uic, you must install drivers for both the 1747uic interface converter and the usb serial port. But i have several 1200s in use and only need to use the 1747uic for the ones that i have on a dh485 network. How to connect to an allenbradley slc 500 plc plc one. Select one or more products to view the available downloads for those products. In the configure drivers available drivers dialog box, select ethernet to plc5 or 5820ei click add new to enter the add new rslinx driver dialog box. Allen bradley 1747uic slc 500 usb to dh485 programming cable. Buy allenbradley 1747uic is a slc 500 usb to dh485. In the mean time, rockwell has released a firmware utility for its 1747uic which allows switching between 9,600 and. To regain comms youll have to edit your driver in rslinx to match the new. Get rockwell automation 1747uic universal serial bus to dh485 interface converter manual.
After the programming cable is connected, first install the 1747uic driver. Then you can go to rslinx or what ever your plc communication software is, and set com port accordingly for rs232 driver in rslinx. If you have an original ab unit, it is possible to change to the baud rate to 9600 by following the steps in this rockwell knowledgebase document requires creating a free account and logging in. Plug the 1747uic usb cable into the computers usb port. Usb dh485 rj45 or 9pin dshell, switch selectable 19200. Jun 07, 2015 hello hewa, i apology for my late answer, you message went to the folder span. Open rslinx, goto communications, configure drivers, in the drop down menu select 1747pic and configure it if needed then try connecting. Allenbradley 1747uic installation instructions manual pdf. Universal serial bus usb to dh485 interface converter 7 install the drivers before using the 1747uic, you must install drivers for both the 1747uic interface converter and the usb serial port. Allenbradley 1747uic driver download list description. Rockwell automation 1747uic universal serial bus to dh. Allen bradley 1747uic installation and rslinx configuration. Uploaded on 4142019, downloaded 418 times, receiving a 86100 rating by 207 users.
You will need to set up the connection in the rslinx. Hello hewa, i apology for my late answer, you message went to the folder span. Allen bradley 1747uic usb to dh485 usb version 1747pic slc. If anybody can tell me how to set rslinx configure driver. Configuration in rslinx uses the same dh485 uic devices driver that the ab part uses. Replace allen bradley 1747uicusb using equustek dl3500df1. Which means that your processor is configured for df1 protocol. Selecting isolation transformers allen bradley 1747uic your hardware components if there is high frequency conducted noise in or around your allen bradley 1747uic isolation distribution equipment, use an isolation transformer in the ac line to transformers the power supply. Select driver from available driver types and press add new button note. It worked great on these fixed units as well as some 503s. The converter also embeds the dh485 driver compatible with the existing rslinx df1 rs232 fullduplex driver, eliminating the need for this driver to be installed. Jul 25, 2012 if that works then you must be using the df1 driver in rslinx. Please login to see product pricing available in select areas. Get your free download of the entire contents of this cd in our drivers, software, and manuals section.
When using a usb to rs232 converter cable with the plc vendors rs485 to rs232 cable, like the ab plc cable, you not only have the electronics, com 1 dependency. Allenbradley 1747 uic driver download list description. There are two methods, rs232 df1 devices i tried ok with my desktop computer, and dh485 uic devices i tried ok with our laptop, if you cant communicate, please try. Electronics free delivery possible on eligible purchases. Communicate and download over dh485 using rslinx and rslogix 500.
Buy allen bradley 1747uicusb to dh485 usb to 1747pic plc interface converter. This is well documented on the rockwell support site. The green ok led indicator should turn on to indicate that the 1747uic is receiving power through the usb port. The uic is a direct replacement for the pic therefore it should use the pic driver in rslinx, at least try it and see what happens. To avoid this, cancel and sign in to youtube on your computer. Configure the new station number in the rslinx df1 driver. Usb 1747 uic windows 7 64 and 32 bit allen bradley dh485. If you are looking for a usb version of the 1747pic 1747uic then this is perfect. Advantages embedded dh485 driver compatible with the existing rslinx df1 rs232 fullduplex driver. The 1747uic adapter only supports 19200 baud out of the box. Alternate 32 bit method you can change the name of the driver if you wish, but it can make it easier to go online if you leave it at the default.
Step 6 now select 1770kf31747ke from the device drop down list. Replace allen bradley 1747uicusb using equustek dl3500. If that works then you must be using the df1 driver in rslinx. While third party 1747uics represent a great price savings versus the rockwell version, and in my own tests they work extremely well, further investigation has not been able to confirm support of multiple baud rates. Open rslinx and go to communications configure drivers. While third party 1747 uic s represent a great price savings versus the rockwell version, and in my own tests they work extremely well, further investigation has not been able to confirm support of multiple baud rates. Youre mileage will vary with the autoconfig feature. Allenbradley 1747uic refurbished and repair service. Why the allenbradley ab 1747pic always had trouble. Change the station number if you want to change the station number when the 1747uic interface converter is already online to a dh485 network with an existing station number, you must. Usb w configuratio f2kf3 ith equu n software an stek dl35 nd select dl3 500 df1 dh 500 models.
Allenbradley 1747uic 1747uic interface module ebay. Rslogix 500 configuring rslinx serial df1 rs232 driver to communicate. The 1747uic enhances the connection of slc500, micrologix, controllogix controllers, panelview terminals, 1747aic and 1761netaic isolators through the dh485 port using a computer usb port. For all the ones that are standalone i only use the usb to serial converter and the programing cable to connect through a df1 driver. To select one or more products from your search listing, you.
956 576 955 190 67 503 120 1365 235 1268 136 1413 1169 1432 365 397 1484 1320 1480 844 419 169 454 1084 501 1103 3 491 451 823 1300 1097 1259 553 1022